Our company pays specific interest to customers’ requirements, listening to the specific demands of each and every client and guaranteeing whole pleasure. The new merchandise incorporate a collection of substantial-tech and high quality chains and sprockets and gears, these kinds of as chains and gearboxes for agricultural machineries, metallurgical chains, escalator phase-chains, higher-speed tooth chains, timing chains, self-lubrication chains, among which have variety high pace tooth chain for car department dynamic box and aerial chains fill in the blanks of chain in China. If you are fascinated in any of our items or would like to talk about a potential buy, please come to feel cost-free to make contact with us. Held-220 Entire-automobile Biochemistry Analyzer
120tests / hour thirty sample positions
sixty reagent positions 81 reaction positions
EPTnical Feature
Performance
Kind: Discrete EPTT
Basic principle: Absorption Spectrometry, Turbidimetry
Throughput: EPTT 120tests/hour (with out ISE)
Take a look at Method: End-point, Fastened-time, EPT
Assist twin reagents/double wavelength
Test sequence: Operate assessments in rigid accordance with sample sequence,
Insert unexpected emergency at any time
On-line Sample: thirty samples/ batch, endless batch enter
Reaction Time: Max 15minutes
Reaction Volume: Mini 150 mul
Cuvette: 81 cuvettes
EPTal Method
LigEPTT Source: Halogen-tungsten lamp, 12V/20W
A lot more than 2000hrs provider time
Spectrometric Approach: Soon after spectrometric approach
Wavelength: 8 wavelengths, selectable amid 340-800nm
Absorption Range: -four.0Abs
EPTal Program: Integrated full shut optical method
Sample method
Sample Tray: 30 positions
Sample Volume: two-100 mul, .one mul by phase,
Sample Probe: Liquid stage detection, anti-collision security and stock checking,
have automatic cease and alarm prompt for an obstacle
Probe Cleansing: EPTT washing for both inside and exterior
Others
Water Use: considerably less than 3L/hour
EPTT EPT: AC 220 plusmn22V 50HZ plusmn1HZ
EPTT: Max 200VA
Ambient Temperature: 10 degC-thirty degC
Reagent Program
Reagent Volume: twenty-five hundred mul, 1 mul by phase
Reagent Tray: sixty positions, open system
Reagent Probe: : Liquid level detection, anti-collision security and inventory examining,
have automated stop and alarm prompt for an impediment
Probe Cleansing: EPTT washing for both inside and exterior
Reagent Bottle: Bottles with 15ml,20ml,30ml,50ml,70ml are accessible
EPT volume lt1ml
Temperature EPTT Technique
EPT Mode: Sound consistent temperature closed immediate heating
Equilibrium Time: much less than 3minutes
Reaction Temperature: 37 plusmn0.2 degC
Temperature Fluctuation: plusmn .two degC
EPTT and Calibration
Calibration Mode: EPT, Logit-4p, Logit-5p, Spline, Aspect, EPTnomial
EPTTally examine calibration curve and choose the calibration sort with the best fitting
QC Type: Real time QC, QC in one working day, QC among times
QC chart: L-J, Cumulative, Twin Plot
QC Policies: Multi-rule default: Westguard
Position Checking: Real -time keep track of the sample tray, reagent tray, reaction tray, reaction cup, lamp, purified water Genuine-time display reaction tray humidity, reagent stay, reaction curve, calibration curve and QC chart.
Inspection and Judgment: Response conclude level judgment, response linear range judgment, substrate depletion judgment, front belt detection,reaction restrict inspection, reagent blank absorbance judgment
Procedure Unit
Operation Method: EPTs operation method
Database: SQL Server
Data Storage: EPTT storage and backup, forever maintain all sorts of info
Print Articles: Print articles can be EPT
Print Format: Provide a assortment of print structure